022293:Cardboard Bursting Strength Tester Machine(110V)
Unit:
set
Price:
1,669.00$
Weight:
87.00kg
QTY:
Out Of Stock
     

Similar products

160229:Color Matching Cabinet 4 light sources: D65 TL84 UV F Size:71*42*57cm

153061:Optical Eyeglasses Display case

027282:Hot and Cold Belt Cutting Machine(Blue panels)

190417:Stair Climbing Hand Truck

219407:Bakery SHowcase

Cardboard Bursting Strength Tester Machine

Attention

Before operating the unit, please read this instruction book thoroughly, and retain it for future reference.Users are responsible for the proper operation and maintenance of the equipment they use. Some equipment will quickly become damaged and unsafe if abused or subjected to improper demands.

Main Parameter
Measurement Range Cardboard 250-5600KPa
Paper 50-1600KPa
Resolution Ratio 0.1KPa
Readout Accuracy ≤±1%F.S
Sample Clamping Force Cardboard >690KPa
Paper >430KPa
Pressure Speed Cardboard 170±15ml/min
Paper 95±5ml/min
Rating of Machine Cardboard 120W
Paper 90W
Film Resistance Cardboard

Bulge 10mm±0.2mm, 170-220KPa

Bulge 18mm±0.2mm, 250-350KPa

Paper

Bulge 9mm±0.2mm, 30±5KPa

Clamp Ring Inside Diameter Upper 31.5±0.05MM
Nether 31.5±0.05MM
Diameter of the Clamp Upper 95mm
Nether 135mm
Material of Clamp Stainless Steel
Hydraulic Oil Should Use Silicone Oil
Size of the Machine 430*530*520mm
Weight of the Machine 70Kg/154Lb
Detail of Machine
 
 
 
OPERATION PANEL

Peak: the maximum value of this experiment

0/40: 0 current stored data; 40 the amount of data that can be stored

F1: zero clearing.

F2: Delete.

F3: increase pressure. After replace the film, use the button. DO NOT press the button at other times.

F4: reduce pressure. After replace the film and increase pressure, use the button. DO NOT press the button at other times.

F5: pneumatic. After replace the film, use the button to debug the machine. DO NOT press the button at other times.

Operating Environment

1. Temperature: 20℃±10℃

2. Voltage: 110V/60Hz, the power should be grounded.

3. Place the machine on a stable surface, NO high-intensity magnetic field, NO vibration source.

4. Relative humidity (RH): 85%.

Item Include(022293)